Skip to main content
Network Switches › ZTE Wantong S2150-S · 2 models
عربي
ZTE Wantong S2150-S Series
ZTE Wantong S2150-10C-S — 8×FE + 2×GE Combo
ZTE Wantong S2150-28C-S — 24×FE + 2×SFP + 2×Combo
ZTE WantongS2150-S Series · FE Access
Fast Ethernet Secure Access Switches · Gigabit Uplinks · 2 Models

ZTE Wantong S2150-S · FE Access

Managed fast-ethernet access switches for campus edges, building broadband and camera or desk access — 8 or 24 FE RJ45 ports with gigabit fiber/copper uplinks, fanless and silent, with ZESR ring protection and zero-touch deployment. We deliver them configured as part of the network solutions we build.

8 / 24 · FE RJ45 access ports2 / 4 · GE uplinks (SFP / Combo)Fanless · silent natural cooling50ms · ZESR / ZESR+ ring protectionM-Button · status check without login
CHOOSE YOUR MODEL — TWO FE ACCESS MODELS
Pick by port count: the 10C-S has 8 FE ports and 2 GE Combo uplinks in a 340 mm desktop/shelf body; the 28C-S has 24 FE ports and 4 GE uplinks (2 SFP + 2 Combo) in a 19-inch 1U body. Software features are the same on both. The table below compares them column by column.
Get Best Price on WhatsAppRequest a quote ↓

Lead time · In stock: at your forwarder’s China warehouse 3 days after payment · Not in stock: 7–15 working days · Then air 5–10 days / sea 25–45 days to your port

Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA

Need the PDF datasheet? Get it on WhatsApp →
In-stock models: 3 days to your forwarder's warehouse in China after payment · Out-of-stock: 7–15 working days · then air 5–10 days or sea 25–45 days to your port

Sample quantities are welcome — testing one or two units first is the normal way to start.

Corporate orders are registered with the manufacturer under your company name — genuine supply you can verify at the source.
8–24FE access ports per unit
64Gswitching capacity (Gbps)
17.1Wmax power draw (28C-S)
50msZESR ring protection class

The ZTE Wantong S2150-S series is the fast-ethernet access line of the ZTE Wantong campus switching family, built for the edge of the network where 100 Mbps per port is enough: IP cameras, desk PCs, IP phones, access control panels and building broadband subscribers. The S2150-10C-S has 8 FE RJ45 ports and 2 GE Combo uplinks; the S2150-28C-S has 24 FE RJ45 ports, 2 GE SFP and 2 GE Combo uplinks. Both are fanless, draw 11 W and 17.1 W at most, and share one software set: 4K VLANs with QinQ and VLAN translation, ZESR/ZESR+ ring protection, IGMP snooping and controllable multicast, dual-direction ACLs, DAI and IP Source Guard, plus zero-touch deployment and M-Button for fast roll-out. The series has no PoE. All specifications are quoted from the manufacturer's datasheet.

Two sizes, one software set

Both models run the same features — the choice comes down to port count, uplinks and mounting.

S2150-10C-S · 1 MODEL
8-port FE access8×FE RJ45 + 2×GE Combo, 4.2 Mpps, 11 W max, 340 mm wide and 2.8 kg. Fits a small wall box, a shelf or a desk: a small office, a shop, a guard post or a cluster of cameras that already have their own power.
S2150-28C-S · 1 MODEL
24-port FE rack access24×FE RJ45 + 2×GE SFP + 2×GE Combo, 15.6 Mpps, 17.1 W max, 19-inch 1U (442 mm) and 3 kg. Four GE uplinks allow a dual-homed or ring connection plus spare ports — the floor switch for building broadband, hotels and office floors.

Is this the right access series for you?

Plain-language guide — based only on what these switches actually do.

Camera and device access at 100 MbpsAn IP camera stream, an IP phone or an access control panel uses far less than 100 Mbps, so FE ports are enough; the GE uplinks carry the combined traffic to the NVR or core. Cameras need their own power or a PoE injector — this series has no PoE.
Building broadband and hotel roomsOne port per apartment or room, with QinQ, 1:1 and 1:N VLAN translation, MFF, port isolation and DHCP Option 82 keeping each subscriber separate, and IGMP snooping with IPTV support for TV services.
Silent rooms and many identical sitesFanless cooling suits offices, classrooms and wiring boxes with no air flow. Zero-touch deployment upgrades and configures batches of identical switches at once, and M-Button shows port, CPU, memory, MAC and loop status on site without logging in.
Not the right pick if you need…
  • Gigabit desk ports or PoE+ for cameras and APs — see the ZTE Wantong S5150 gigabit access series, or the S1000 SMB series for simple PoE
  • 10G uplinks — the ZTE Wantong S5160-HE series adds 10G uplinks on gigabit access, and the S5860-E series handles 10G aggregation
  • A routing gateway with dynamic routing between VLANs — the ZTE Wantong S5860-S smart L3 routing switches cover that

Worried about the source? Order under your own company name.

For corporate buyers: we support submitting the purchase order to the manufacturer under your company's real name — your company appears on the official order, so the origin of the goods can be verified directly with the factory. Just provide your company name and pay by corporate bank transfer.

1 · Company name2 · Corporate bank payment3 · Order registered in your name

Using your own freight forwarder? No problem.

For small and mid-size orders, we deliver directly to your designated forwarder's warehouse in China — EXW or FOB, your choice, each quoted separately. From hand-over onward, international shipping and destination-side arrangements are handled by your forwarder — the way you already work.

EXW / FOBDelivery to your forwarder's warehouseNo minimum order
Note: manufacturer order registration (left) is available via the corporate purchase channel.
How to get a better price
Volume DiscountBulk quantities of a single model
CONTACT US
Mix & Match DiscountMix any categories & models storewide in one order — no quantity limit
BETTER
Verified Project PriceDistributor, integrator or end user with a real project? Send the BOQ — project pricing plus free network design. Partner projects are protected: we never quote your end customer behind you
BEST
All discounts are quoted personally — message me on WhatsApp ↑

Key Features

The series capability list — from the manufacturer's datasheet.

GE Combo uplinks selectable as copper or fiber, with FE (100M) optical module support
Zero-touch deployment: batch software upgrade and configuration of many identical switches, plug-and-play
M-Button: port, memory, CPU, traffic, MAC learning and loop status without logging in
ZESR / ZESR+ ring and ZESS dual-uplink protection, 50ms class, with multi-instance load sharing
1:1 and 1:N VLAN translation, QinQ and flexible QinQ, Voice VLAN with QoS priority
L2 multicast: IGMP v1/v2/v3 snooping, controllable multicast, MVR, IPTV and source-MAC specific on-demand
Security: dual-direction ACLs, DAI, IP Source Guard, MFF, 802.1x / RADIUS, port isolation, storm suppression
Console, Web, Telnet, SSH and SNMP v1/v2/v3 management, sFlow, RSPAN, dual software image backup; fanless design

Who uses it, where it goes and how to plan FE access

Written for the ZTE Wantong S2150-S access series from its own specifications: 2 fanless models with 8 or 24 FE RJ45 ports, 2 or 4 GE uplinks, 64 Gbps switching capacity, 11–17.1 W maximum power, no PoE.

Who it is for

  • ISPs and building-broadband operators — One FE port per subscriber, with QinQ, 1:1 and 1:N VLAN translation, MFF, port isolation and DHCP Option 82 keeping customers apart, and SNMP v1/v2/v3, RADIUS/TACACS+ and NetNumen U31 for the operator's NMS.
  • CCTV and access-control installers — Managed edge switch for cameras, door controllers and alarm panels that already have their own power: VLANs separate the camera network, IGMP snooping keeps multicast video off other ports, and GE fiber uplinks reach the NVR room.
  • Schools, hotels and SME offices — Silent fanless access for classrooms, guest rooms and office desks where 100 Mbps per user is enough; Voice VLAN for IP phones and 802.1x/RADIUS so only approved devices get on the network.
  • Integrators rolling out many small sites — Branches, shops or substations with identical switches: zero-touch deployment and the Easy Manager batch tool push software and configuration in one go, and ZGMP cluster management handles many units from one point.

Where and how to install

  • Rack, wall box or desk — Both models are 43.6 mm (1U) high and 220 mm deep, so they fit a shallow wall cabinet. The S2150-28C-S is 442 mm wide for a 19-inch rack; the S2150-10C-S is 340 mm wide, narrower than 19 inches, so use a shelf, a wall box or a desktop position.
  • Power — Single AC input, 100–240 V, 50–60 Hz, with a maximum draw of 11 W (10C-S) or 17.1 W (28C-S), so a small UPS keeps them running for a long time. There is no redundant power input, so the UPS is the redundancy; the power-loss alarm reports outages to the NMS.
  • Cooling and temperature — Fanless natural cooling, rated -5°C to +50°C at 10%–90% humidity and below 3000 m altitude, with 33 or 55 BTU/h heat output. With no fan, nothing pulls air through the case, so leave space around the vents and keep the switch away from hot devices in a closed box.
  • Fiber or copper uplinks — The 10C-S has 2 GE Combo uplinks (each one either RJ45 or SFP); the 28C-S adds 2 dedicated GE SFP ports. Use fiber for any run over 100 m or between buildings, and fit the same module type and wavelength at both ends; the Combo ports also accept FE optical modules for older fiber links.
  • Management network — Put each switch's management IP in a dedicated management VLAN reachable only from the NOC, and use SSH and SNMP v3 rather than Telnet. Both models have an out-of-band management port and an RJ45 console port; label them and keep a console cable in the cabinet for first setup and recovery.

S2150-S series planning: which of the 2 models

Both are fanless FE access switches with GE uplinks and the same software; they differ in port count, number of uplinks and width. Neither has PoE. Uplink bandwidth is the sum of the GE uplinks; for camera sites, add up your streams (for example about 8 Mbps per camera) and keep the total well under the uplink you actually use.

10C-S28C-S
Access ports8×FE RJ4524×FE RJ45
Uplinks2×GE Combo2×GE SFP + 2×GE Combo
Total GE uplink bandwidth2 Gbps4 Gbps
10G / 25G / 40G / 100G uplink——
Switching capacity64 Gbps64 Gbps
Packet forwarding rate4.2 Mpps15.6 Mpps
Max power consumption11 W17.1 W
Width / mounting340 mm / shelf or desktop442 mm / 19-inch 1U
L3 routingstatic IPv4 / IPv6static IPv4 / IPv6
Power redundancy / coolingsingle AC / fanlesssingle AC / fanless
Typical positionFE desk / camera access, small officeFE floor access, building broadband
  • Pick the S2150-10C-S for a small office, shop or guard post with up to 8 devices: one Combo port uplinks over fiber or copper and the other stays free for a second path.
  • Pick the S2150-28C-S for a building floor or a ring: two SFP ports can close a ZESR ring while the two Combo ports stay available for local uplinks or expansion.
  • If the devices need PoE or gigabit ports, this is the wrong series: look at the S5150 gigabit access series or the S1000 SMB PoE switches instead.

— = not listed on the page / not applicable. Values are from the page's specification tables; total uplink bandwidth is arithmetic (number of GE uplinks × 1 Gbps). The manufacturer lists no PoE for this series.

Full Specifications — Model by Model

Series specifications with one column per model — technical values in English. The highlighted column follows your model selection above.

S2150-S Series — Hardware & Environment (2 models)

Item10C-S28C-S
Fixed ports8×FE RJ45 + 2×GE Combo24×FE RJ45 + 2×GE SFP + 2×GE Combo
Switching capacity64 Gbps
Packet forwarding rate4.2 Mpps15.6 Mpps
Console1×console port (RS232, RJ45)
Management portOut-of-band management Ethernet port
Dimensions (H×W×D)43.6×340×220 mm43.6×442×220 mm
Max weight2.8 kg3 kg
AC power100–240 V, 50–60 Hz, single power supply
Max power consumption11 W17.1 W
CoolingFanless, natural cooling
Max heat dissipation33 BTU/h55 BTU/h
Operating environment-5°C to +50°C, humidity 10%–90%
Operating altitude< 3000 m
MTBF / MTTR> 100,000 hours / < 30 minutes

S2150-S Series — Software Features (both models)

Item10C-S28C-S
MACIEEE 802.1d automatic MAC address learning / MAC address aging / port-MAC binding / per-port MAC learning limit
Port featuresJumbo frames up to 10K bytes / speed and duplex auto-negotiation / MDI/MDIX auto-crossover / Virtual Cable Test / port loopback test / broadcast, multicast and unknown-unicast suppression
Link aggregationIEEE 802.3ad LACP / static trunk / max 15 groups, max 8 ports per group
MirroringPort mirroring of ingress, egress or both directions / one-to-one, many-to-one, many-to-many / flow-based mirroring / RSPAN remote mirroring
VLAN4K VLANs / port-, protocol-, IP-subnet- and MAC-based VLAN / Voice VLAN / VLAN translation (1:1, 1:N) / PVLAN / QinQ and flexible QinQ / GVRP
Ring & link protectionSTP / RSTP / MSTP / ZESR / ZESR+ ring protection (50 ms class) / ZESS (ZTE Ethernet Smart Switch) link protection
DHCPDHCP Snooping / DHCP Relay / DHCP Option 82
IP routingIPv4 static routing / IPv6 static routing
IPv6IPv6 Ping, IPv6 Telnet / ND (Neighbor Discovery) / MLD Snooping / DHCPv6 Snooping / IPv6 ACL
MulticastIGMP v1/v2/v3 / IGMP snooping, filtering, proxy and fast leave / controllable multicast, CAC channel access control / MVR multicast VLAN registration / user multicast access control and access logging
ACLMAC- and IP-based standard ACL / L2, extended (5-tuple), hybrid, user-defined and VLAN ACLs / time-based ACLs / ACLs in both ingress and egress directions
QoSPort- and flow-based bandwidth management / 8 hardware queues per port / 802.1p and IP DSCP marking, remarking and mapping / SP, WRR, SP+WRR scheduling / tail-drop congestion avoidance
SecurityHierarchical user management and password protection / CPU anti-attack and CPU overload protection / broadcast-multicast-unknown-unicast suppression / port isolation / Dynamic ARP Inspection / 802.1x with RADIUS authentication / STP Root Guard and BPDU attack protection / IP Source Guard / MFF
Ease of maintenanceM-Button / zero-touch deployment / dual backup of software image
Device managementRS232 console (RJ45) / out-of-band management port / CLI, Telnet, SSH / Web / FTP, TFTP / local and remote (RADIUS/TACACS+) login authentication and authorization / SNMP v1/v2/v3 / DHCP client / NetNumen U31 NMS / Easy Manager zero-touch and batch inspection tool / cluster management (ZGMP) / NTP, Syslog, RMON / sFlow / power-loss alarm
Engineer's note: The Combo uplinks take either a copper cable or an SFP module, and FE (100M) optical modules are supported as well as GE — tell us the fiber type and distance and we will match the optics. The series has no PoE, so we also list the injectors or PoE switch your cameras need. Send us your port plan and we will put together the whole configuration and SFP matching list free of charge.

Fast Ethernet Access Switch FAQ — S2150-S Series

What is the difference between the S2150-10C-S and the S2150-28C-S?
Only the hardware size differs. The 10C-S has 8 FE RJ45 ports and 2 GE Combo uplinks, 4.2 Mpps and 11 W maximum in a 340 mm wide body; the 28C-S has 24 FE RJ45 ports, 2 GE SFP and 2 GE Combo uplinks, 15.6 Mpps and 17.1 W maximum in a 19-inch 1U body. Both list 64 Gbps switching capacity and the same software features.
Are 100 Mbps access ports enough for IP cameras?
For one camera per port, yes: a typical camera stream is a few Mbps, far below 100 Mbps. What matters is the uplink: 24 cameras at about 8 Mbps add up to roughly 192 Mbps, within one GE uplink of the 28C-S, and you can bundle uplinks with LACP if needed. The series has no PoE, so cameras need local power or PoE injectors.
Can the S2150-S power cameras or access points over PoE?
No. The manufacturer lists no PoE for either model; the maximum power consumption of 11 W and 17.1 W covers the switch itself. For PoE devices, use PoE injectors, or choose a PoE switch such as the PoE models of the ZTE Wantong S5150 series or the S1000 SMB PoE switches.
How fast does the ring recover if a fiber link is cut?
With ZESR or ZESR+ the manufacturer specifies 50 ms-class protection, for closed rings, open rings and dual-uplink topologies, with multi-instance load sharing so both directions carry traffic. ZESS adds smart link protection for dual uplinks, and STP, RSTP and MSTP are available when the ring includes other brands. The 28C-S, with 4 GE uplinks, can join a ring and still keep spare uplinks.
Can the S2150-S act as the gateway and route between VLANs?
It is an access switch: the specification table lists IPv4 and IPv6 static routing only, with DHCP Snooping, DHCP Relay and Option 82 for address control. For a site gateway with dynamic routing between VLANs, put an L3 switch above it, such as the ZTE Wantong S5860-S or S5860-E series, and let the S2150-S handle the edge ports.
Can I order under my own company name and use my own forwarder?
Yes to both. Corporate buyers can have the purchase order submitted to the manufacturer under their own company name, so your company appears on the official order. For small and mid-size orders we also deliver directly to your designated forwarder's warehouse in China on EXW or FOB terms.
Which SFP modules can I use in the S2150-S uplink ports?
The uplinks are GE SFP and GE Combo ports, so use 1G SFP modules; the manufacturer also states that the Combo ports support FE (100M) optics, which helps when the far end is an older 100M fiber link. 10G SFP+ modules are not listed. A third-party compatibility list is not published, so send us the module you plan to use or let us supply matched optics, and use the same fiber type and wavelength at both ends.
Can the S2150-S work in a network built on Huawei, H3C or Cisco switches?
Yes, through standard protocols: 802.1Q VLANs and trunks, 802.3ad LACP, 802.1p/DSCP QoS, STP/RSTP/MSTP, 802.1x with RADIUS, SNMP v1/v2/v3, Syslog and sFlow. ZESR/ZESR+, ZESS and ZGMP are ZTE Wantong features, so in a ring with other brands use MSTP instead. The CLI is its own command set, so configuration templates need to be translated rather than pasted.
How do I keep apartments or hotel rooms isolated from each other on one S2150-S?
Use port isolation or PVLAN so subscriber ports cannot talk to each other, or MFF, which isolates hosts at Layer 2 inside one broadcast domain while still letting them reach the gateway. QinQ and 1:1 or 1:N VLAN translation map each room to the operator's VLAN plan, and DHCP Snooping with Option 82, DAI and IP Source Guard stop address spoofing.
What do zero-touch deployment and M-Button change for a large roll-out?
Zero-touch deployment lets you upgrade software and push configuration to a large number of identical switches at once, so installers only cable and power them. On site, M-Button shows port, memory, CPU, traffic, MAC learning and loop status without logging in; the manufacturer states this cuts routine check time by more than 80%. Dual software image backup gives a fallback if an upgrade fails.
Can the S2150-S carry IPTV or multicast video without flooding every port?
Yes. IGMP v1/v2/v3 snooping, proxy and fast leave send each stream only to the ports that joined it, and MVR keeps one copy of the multicast VLAN for all subscribers. Controllable multicast with CAC channel access control decides which users may watch which channels, and the IPTV general group and source-MAC specific on-demand functions are listed for TV services.
Can I order one unit first, and how does it reach my country?
Yes — a single sample can be ordered and sent by air. For larger orders we deliver EXW or FOB to your freight forwarder's warehouse in China, or arrange air or sea freight to your country on request. Every shipment comes with a commercial invoice and packing list for customs; import duties and VAT in your country are not included unless agreed in writing.
How do I pay?
By bank transfer (T/T) in US dollars against our proforma invoice, which lists the model, quantity, unit price, delivery terms and lead time. You can check our company details on the verification page before you pay.

Request a quote for this product

An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.

Product: ZTE Wantong S2150-S · FE Access

Or ask on WhatsApp

Zhengzhou Huamai Information Technology Co., Ltd. · Tel / WhatsApp +86 186 1168 3168 · info@atlascommtech.com