ZTE Wantong S5160-HE · Gigabit Access + 10G
Full-gigabit access switches for enterprise and campus networks, with 24 or 48 GE ports, four 10GE SFP+ uplinks on every model and a PoE+ option with a 370 W budget. We deliver them configured as part of the network solutions we build.
Lead time · In stock: at your forwarder’s China warehouse 3 days after payment · Not in stock: 7–15 working days · Then air 5–10 days / sea 25–45 days to your port
Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA
Need the PDF datasheet? Get it on WhatsApp →Sample quantities are welcome — testing one or two units first is the normal way to start.
The ZTE Wantong S5160-HE series is a full-gigabit box switch for enterprise desktop access and small aggregation. The four models offer 24 or 48 GE RJ45 ports, and every one has four 10GE SFP+ uplinks, so a floor switch can reach the aggregation layer at 10G instead of 1G. Switching capacity is 432 Gbps / 4.32 Tbps on all models, with 156/168 Mpps on the 28-port and 196/222 Mpps on the 52-port units. The PX models add 802.3af/at PoE+ at up to 30 W per port and 370 W per unit. Software is shared: static/RIP/OSPF and IPv6 routing, L2/L3 multicast, ERPS/ZESR rings, MC-LAG, VSC clustering and zero-touch deployment. All values below come from the manufacturer's documents; fields that were not published are left out.
Two hardware lines, one software platform
How the X and PX models split the job — so you order the one that actually fits.
Is this the right access series for you?
Plain-language guide — based only on what these switches actually do.
- An aggregation or data-centre switch with dense 10G/25G/100G ports — that's the ZTE Wantong S6850-X series, or the S5860-E series for 10G aggregation
- A chassis-based network core — the ZTE Wantong S7850 modular core series covers that
- Plain gigabit access with 1G SFP uplinks on a tighter budget — the ZTE Wantong S5150 series, or the S2150-S and S1000 SMB lines for FE or unmanaged switching
Worried about the source? Order under your own company name.
For corporate buyers: we support submitting the purchase order to the manufacturer under your company's real name — your company appears on the official order, so the origin of the goods can be verified directly with the factory. Just provide your company name and pay by corporate bank transfer.
Using your own freight forwarder? No problem.
For small and mid-size orders, we deliver directly to your designated forwarder's warehouse in China — EXW or FOB, your choice, each quoted separately. From hand-over onward, international shipping and destination-side arrangements are handled by your forwarder — the way you already work.
Key Features
The series capability list — from the manufacturer's datasheet.
Who uses it, where it goes and how to plan the access layer
Written for the ZTE Wantong S5160-HE series from its own specifications: 4 models with 24 or 48 GE ports, 4×10GE SFP+ uplinks on every model, PoE+ up to 30 W per port and 370 W per unit on the PX models, static/RIP/OSPF routing.
Who it is for
- Enterprise IT and office buildings — One switch per floor or wiring closet: 24 or 48 GE desk ports, Voice VLAN for IP phones, 802.1x/Portal/MAC authentication with RADIUS, and a 10G uplink so busy floors are not limited by a 1G link.
- Campus, school and government projects — Many identical access switches under one aggregation layer: zero-touch deployment, automatic configuration download and remote batch upgrade cut on-site work, and VSC clustering lets several units be managed as one.
- CCTV and Wi-Fi integrators — The 28PX-HE and 52PX-HE power cameras and APs at up to 30 W per port from 370 W, while the 10GE SFP+ uplinks carry many camera streams to the NVR room without a 1G bottleneck.
- ISPs and building-broadband operators — At the subscriber edge, QinQ, flexible QinQ, VLAN translation, PVLAN and MFF keep customers separated, Ethernet OAM (EFM, CFM, Y.1731) helps fault-finding, and SNMP v1/v2/v3 and sFlow feed the operator's NMS.
Where and how to install
- Rack or wall cabinet — All models are 43.6 mm (1U) high and 442 mm wide for a 19-inch rack. The S5160-28X-HE is 208 mm deep and fits a shallow wall cabinet; the other three are 330 mm deep, so check the cabinet depth and leave room for cables at the front.
- Power — All models take AC 100–240 V, 50–60 Hz, from a single power supply. A loaded PX unit can draw up to 430 W, so give the cabinet its own protected circuit and size the UPS for the PoE load; the X models draw only 40 W or 60 W.
- Cooling and temperature — The X models are fanless with natural cooling and are rated -10°C to +45°C; the PX models use forced air with temperature-controlled fans and are rated -10°C to +50°C. Keep the vents clear and do not stack the switches tightly against other hot equipment in a closed cabinet.
- 10G fibre uplinks to aggregation — Every model has 4×10GE SFP+ uplinks. Use fibre for runs over 100 m or between buildings, with the same type of 10G module at both ends; two uplinks to two aggregation switches can be protected with MC-LAG, ZESS or an ERPS/ZESR ring.
- Management network — Put each switch's management IP in a dedicated management VLAN reachable only from the NOC, and use SSHv2 and SNMP v3 rather than Telnet. Label the RJ45 console port and keep a console cable in the cabinet for first setup and recovery.
S5160-HE series planning: which of the 4 models
All four are full-gigabit access switches with 4×10GE SFP+ uplinks and the same routing software; they differ in port count and PoE. Camera counts assume about 6 W per typical fixed IP camera and 30 W per port for PTZ cameras or high-power APs; the real limit is whichever runs out first, ports or budget.
| 28X-HE | 52X-HE | 28PX-HE | 52PX-HE | |
|---|---|---|---|---|
| Access ports | 24×GE | 48×GE | 24×GE PoE+ | 48×GE PoE+ |
| Uplinks | 4×10GE SFP+ | 4×10GE SFP+ | 4×10GE SFP+ | 4×10GE SFP+ |
| 10G / 25G / 40G / 100G uplink | 4×10G | 4×10G | 4×10G | 4×10G |
| Switching capacity | 432 Gbps | 432 Gbps | 432 Gbps | 432 Gbps |
| Packet forwarding rate | 156 / 168 Mpps | 196 / 222 Mpps | 156 / 168 Mpps | 196 / 222 Mpps |
| PoE budget per unit | — | — | 370 W | 370 W |
| Cameras at ~6 W (ports or budget) | — | — | 24 | 48 |
| Ports at full 30 W at once | — | — | 12 | 12 |
| L3 routing | static / RIP / OSPF / RIPng / OSPFv3 | static / RIP / OSPF / RIPng / OSPFv3 | static / RIP / OSPF / RIPng / OSPFv3 | static / RIP / OSPF / RIPng / OSPFv3 |
| Power / cooling | single AC / fanless | single AC / fanless | single built-in PSU / forced air | single built-in PSU / forced air |
| Typical position | access, 10G uplink | access, 10G uplink | PoE access, 10G uplink | PoE access, 10G uplink |
- Pick the S5160-28PX-HE for a camera floor of up to 24 devices: 370 W covers all 24 ports at ~6 W, or 12 PTZ-class ports at a full 30 W.
- Pick the S5160-52PX-HE when 48 cameras or APs share one cabinet; its 370 W feeds 48 ports at ~6 W but only 12 ports at a full 30 W, so split high-power APs across switches.
- Pick the S5160-28X-HE or 52X-HE for silent office and classroom racks: no fan, 40 W or 60 W maximum, and the 28X-HE is only 208 mm deep.
— = not applicable. Values are from the manufacturer's specification table; switching capacity is shown as the first of the two published figures (432 Gbps / 4.32 Tbps). Camera counts are arithmetic: budget ÷ assumed watts per port, capped at the number of PoE ports.
Full Specifications — Model by Model
Series specifications with one column per model — technical values in English. The highlighted column follows your model selection above.
S5160-HE Hardware — Non-PoE (X) and PoE+ (PX) Models (4 models)
| Item | 28X-HE | 52X-HE | 28PX-HE | 52PX-HE |
|---|---|---|---|---|
| Fixed ports | 24×GE RJ45 + 4×10GE SFP+ | 48×GE RJ45 + 4×10GE SFP+ | 24×GE (PoE+) + 4×10GE SFP+ | 48×GE (PoE+) + 4×10GE SFP+ |
| Switching capacity | 432 Gbps / 4.32 Tbps | |||
| Packet forwarding rate | 156 Mpps / 168 Mpps | 196 Mpps / 222 Mpps | 156 Mpps / 168 Mpps | 196 Mpps / 222 Mpps |
| Jumbo frame | 10K | |||
| Console | 1×RJ45 console port | |||
| Dimensions (H×W×D) | 43.6×442×208 mm | 43.6×442×330 mm | 43.6×442×330 mm | 43.6×442×330 mm |
| Weight | 2.25 kg | 4.25 kg | 2.95 kg | 5.46 kg |
| Power supply | Single AC power supply | Single AC power supply | 1×built-in power supply | 1×built-in power supply |
| AC power | 100–240 V, 50–60 Hz | |||
| PoE | Not supported | Not supported | IEEE 802.3af/at, 30 W max per port | IEEE 802.3af/at, 30 W max per port |
| Max power consumption | 40 W | 60 W | < 430 W (PoE: 370 W) | < 430 W (PoE: 370 W) |
| Cooling | Natural (fanless) | Natural (fanless) | Forced air (fan speed follows internal temperature) | Forced air (fan speed follows internal temperature) |
| Operating temperature | -10°C to +45°C | -10°C to +45°C | -10°C to +50°C | -10°C to +50°C |
| Operating humidity | 5%–95% | |||
| Operating altitude | < 5000 m | |||
| MTBF / MTTR | > 300,000 hours / < 30 minutes | |||
| Energy saving | IEEE 802.3az EEE (up to 70% lower power per idle port) | |||
S5160-HE Software & Service Features (all 4 models)
| Item | 28X-HE | 52X-HE | 28PX-HE | 52PX-HE |
|---|---|---|---|---|
| L2 features | 802.1p (CoS), 802.1q (VLAN), 802.3x / STP, RSTP, MSTP, EVST / port- & MAC-based VLAN, Voice VLAN / QinQ & flexible QinQ / PVLAN / VLAN translation / port & flow mirroring / GVRP / MAC binding, filtering & dynamic learning / MAC OAM | |||
| L3 features | IPv4 static routing, policy routing, RIP, OSPF / IPv6 static routing, policy routing, RIPng, OSPFv3 / ARP, Ping, Tracert, Telnet / ND, IPv6 Ping, Tracert, Telnet | |||
| Multicast | IGMP v1/v2/v3 snooping / CAC / MVR / MLD Snooping / PIM Snooping / IGMP v1/v2/v3 / PIM DM/SM/SSM / MSDP / static multicast | |||
| QoS | L2–L4 packet filtering; flow classification by source/destination MAC, IP, TCP/UDP port, protocol, VLAN / 8 hardware queues per port / SP, WRR, SP+WRR scheduling / tail-drop congestion avoidance / traffic policing & shaping | |||
| ACL | Standard, VLAN-based, link, extended, hybrid and IPv6 ACLs / time-based ACLs / ACLs in both directions | |||
| PoE standards | PoE (IEEE 802.3af), PoE+ (IEEE 802.3at) — PX models only / extended detection & forced power for non-standard PDs / overload, short-circuit, open-circuit and surge protection | |||
| Security | 802.1x / Portal / MAC authentication / AAA, RADIUS, TACACS+ / SSHv2 / CPU anti-attack / STP root guard, BPDU guard, IP Source Guard / DAI / DHCP Relay, DHCP Snooping / DHCPv6 Relay, DHCPv6 Snooping / broadcast storm suppression / MFF (MAC Forced Forwarding) | |||
| Reliability | LACP link aggregation / MC-LAG / ERPS, ZESR ring protection, ZESS dual-uplink switching (50 ms class) / LLDP, LLDP-MED / Ethernet OAM (EFM, CFM, Y.1731) / UDLD / Ping detection | |||
| Device management | CLI, Telnet, SSHv2 / local & remote (RADIUS/TACACS+) authentication / SNMP v1/v2/v3 / RMON / NTP / FTP, TFTP, SFTP / Syslog, sFlow | |||
| Ease of maintenance | VSC (Virtual Switch Cluster) / zero-touch deployment / auto configuration download / remote batch upgrade / hot patching / cable diagnostics & test / port loopback detection | |||
Gigabit Access Switch with 10G Uplinks FAQ — S5160-HE Series
How do I choose between the four S5160-HE models?
How many IP cameras can the S5160-52PX-HE power?
What do I plug into the 10GE SFP+ uplink ports?
Can the S5160-HE route between VLANs and act as a gateway?
What redundancy options does the S5160-HE offer for uplinks?
Can I order under my own company name and use my own forwarder?
How is the S5160-HE different from the S5150-SE access switches?
Can the S5160-HE work in a network built on Huawei, H3C or Cisco switches?
How does zero-touch deployment help when rolling out many S5160-HE switches?
What UPS do I need for an S5160-PX-HE switch powering cameras?
Which S5160-HE models are silent enough for an office or classroom?
Can I order one unit first, and how does it reach my country?
How do I pay?
Related Products



Request a quote for this product
An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.
Product: ZTE Wantong S5160-HE · Gigabit Access + 10G