Skip to main content
Home › Industrial Switches › ZJIES6028M-HI-24GT4S+

ZJIES6028M-HI-24GT4S+

Unmanaged · Copper + Fiber Hybrid
Unmanaged Industrial DIN-Rail Switch · 6×FE Copper + 4×GE Fixed Fiber · AC 220V / DC 24V/48V
Project-Based Pricing
Volume & combo discounts — get your quote
In-stock models: 3 days to your forwarder's warehouse in China after payment · Out-of-stock: 7–15 working days · then air 5–10 days or sea 25–45 days to your port
✓ Project-level customization & OEM supported
Get Best Price on WhatsAppRequest a quote ↓

Terms · Sample orders welcome · Quotation / PI fixes models, prices, Incoterms (EXW or FOB, each quoted separately), lead time and T/T payment · Defective units: free spare units agreed per order (quantity depends on order size) and written into the quotation · Warranty: up to 5 years on Zhongxin Shutong industrial switches, manufacturer warranty on other brands · Full terms, warranty & RMA

Need the PDF datasheet? Get it on WhatsApp →
How to get a better price
Volume DiscountOrder 50+ pcs of this model
CONTACT US
Project Combo DiscountMix any categories & models storewide in one order — no quantity limit
BIGGER
Verified Project DiscountDistributor, integrator or end user with a real project? Send the BOQ — project pricing plus free system design. Partner projects are protected: we never quote your end customer behind you
BIGGEST
All discounts are quoted personally — message me on WhatsApp ↑
◆Fast Ethernet + Gigabit Fiber
◆Unmanaged Plug&Play
◆DIN-Rail / Wall Mount
◆AC220V / DC24V/48V
◆-40 ~ 75°C · IP40 Enclosure
◆5-Year Warranty

Overview

The ZJIES6028M-HI-24GT4S+ series is an unmanaged DIN-rail switch with fiber uplinks, combining 6 × 10/100Base-T copper access ports with 4 × fixed 10/100/1000Base-FX Gigabit fiber ports (SC, ST or FC connector optional, single- or dual-fiber optional) in one compact unit. It is plug-and-play with no configuration required, uses store-and-forward switching, and ships in a compact IP40 metal enclosure (45×175×143 mm) for DIN-rail or wall mounting. Powered by AC 220V (100–240V) single input or DC 24V (12–36V) / 48V (36–56V) redundant dual input with reverse-polarity and overload protection, it operates from -40 to +75°C — suited for sites that need to aggregate several near-end copper links onto a long-haul Gigabit fiber uplink.

Is This the Right Fit?

Six real deployment scenarios matched to this model's actual datasheet specifications.

DIN-Rail Cabinet Installation, Any Power TypeThree selectable power inputs — AC 220V (100–240V) single input, DC 24V (12–36V) redundant, or DC 48V (36–56V) redundant — and a compact 45×175×143 mm DIN-rail (or wall-mount) body fit directly into a standard electrical cabinet.
Long-Haul Fiber Backhaul for Roadside & Perimeter SitesThe 4 fixed 10/100/1000Base-FX Gigabit fiber ports (SC/ST/FC connector optional) reach up to 2 km over multimode or 20/40/60/120 km over single-mode, long enough to backhaul roadside or perimeter camera clusters to a control room.
Copper Access + Fiber Uplink AggregationThe 6 × 10/100Base-T copper ports collect traffic from local end devices while the 4 fixed Gigabit fiber ports carry it out over a long-distance fiber uplink — suited for sites mixing near-end copper drops with a fiber backbone.
Built-In Media Conversion — No Separate Converter NeededBecause the 4 fiber ports are factory-fixed (not SFP slots), with connector type (SC/ST/FC) and single-/dual-fiber preset at order, each port doubles as a copper-to-fiber media converter — saving a standalone converter at every copper/fiber junction point.
Extreme-Temperature Outdoor CabinetsA wide operating range of -40 to +75°C (-40 to +85°C storage) plus EN61000-4 Level 3 EMC immunity suit unheated roadside cabinets and unconditioned equipment rooms.
Redundant Power for Tunnel & Underground M&E RoomsThe DC 24V (12–36V) or DC 48V (36–56V) models take dual redundant input with reverse-polarity and overload protection, while an AC 220V single-input model is also available — matched to whichever supply is already run in tunnel or underground utility rooms.
Not a good fit if:
  • Unmanaged switch — no VLAN, RSTP/MSTP ring redundancy, or web-based management; choose a managed model for segmented or ring-topology networks.
  • No PoE output on any of the 6 copper ports — cameras, APs, or IP phones needing PoE power require an external injector or a PoE-capable switch.
  • Fiber connector type (SC/ST/FC) and distance class (multimode/single-mode) are fixed at the factory per order — they cannot be swapped in the field the way SFP modules can.

Key Features

  • Unmanaged plug-and-play — zero configuration
  • Up to 6 × 10/100Base-T Fast Ethernet copper ports
  • Up to 4 × fixed 10/100/1000Base-FX Gigabit fiber ports (SC/ST/FC optional)
  • AC 220V (100–240V) or DC 24V/48V redundant dual input
  • DIN-rail mounting (default) · wall-mount optional · compact 45×175×143 mm
  • IP40 metal enclosure · wide temperature -40 ~ +75°C
  • Reverse-polarity & overload protection · 5-year warranty

Specifications

IEEE Standards

IEEE802.310BaseT Ethernet
IEEE802.3u100Base-T(X) & 100Base-FX Fast Ethernet
IEEE802.3z1000Base-X Ethernet
IEEE802.3xFlow Control

Switching

MAC Address Table4K
Packet Buffer1 Mbit
ForwardingStore-and-forward

Interfaces

RJ45 Ports6 × 10/100Base-T
Fiber Ports4 × fixed 10/100/1000Base-FX, single-/multi-mode optional, SC/ST/FC optional, single-/dual-fiber optional
Fiber DistanceMultimode 2 km; single-mode 20/40/60/120 km optional
LED IndicatorsPower, Copper Link, Fiber Link

Power

DC 24V Input4-pin terminal, dual redundant input; DC 24V, range 12–36V DC
DC 48V Input4-pin terminal, dual redundant input; DC 48V, range 36–56V DC
AC 220V Input4-pin terminal, single power; AC 220V, range 100–240V AC
Power ConsumptionMax 6 W
Power ProtectionReverse-polarity & overload

Physical

HousingIP40 metal enclosure
MountingDIN-rail (default), wall-mount optional
Dimensions45 (W) × 175 (H) × 143 (D) mm

Certification

EMCCE, FCC
EMIFCC Part 15, EN 55032 (CISPR 32) Class A
EMSEN61000-4-2/3/4/5/6/8 Level 3
ShockIEC60068-2-27
Free FallIEC60068-2-32
VibrationIEC60068-2-6
GreenRoHS, WEEE

Environment

Standard Temp-10 ~ +60°C
Wide Temp-40 ~ +75°C
Storage Temp-40 ~ +85°C
Humidity5–95% non-condensing

Reliability

MTBF320,000 hours
Warranty5 years

Models & Ordering

ModelProduct DescriptionPrice
ZJIES6028M-HI-24GT4S+-ACUnmanaged industrial DIN-rail switch — 6 × 10/100Base-T + 4 × fixed 10/100/1000Base-FX Gigabit fiber (SC/ST/FC optional), AC 220V (100–240V).✆ WhatsApp
ZJIES6028M-HI-24GT4S+-DCLUnmanaged industrial DIN-rail switch — 6 × 10/100Base-T + 4 × fixed 10/100/1000Base-FX Gigabit fiber (SC/ST/FC optional), DC 24V (12–36V), redundant input.✆ WhatsApp
ZJIES6028M-HI-24GT4S+-DCHUnmanaged industrial DIN-rail switch — 6 × 10/100Base-T + 4 × fixed 10/100/1000Base-FX Gigabit fiber (SC/ST/FC optional), DC 48V (36–56V), redundant input.✆ WhatsApp

All three configurations share the same port layout — 6 × 10/100Base-T copper + 4 × fixed 10/100/1000Base-FX Gigabit fiber (SC/ST/FC connector, single-/dual-fiber optional; multimode 2 km or single-mode 20/40/60/120 km). They differ only in power input: -AC = AC 220V (100–240V) single input; -DCL = DC 24V (12–36V) redundant dual input; -DCH = DC 48V (36–56V) redundant dual input.

Dimensions

ZJIES6028M-HI-24GT4S+ dimensions drawing in mm
unit: mm
Your Brand. Factory-Direct Supply.Neutral casing, ready for your logo · Custom port/power options · Small batches welcome.
Custom & OEM →

Who uses it, where it goes and how to install it

Written for the ZJIES6028M-HI-24GT4S+ from its datasheet: managed Layer 3 rack switch, 24 Gigabit copper ports, 4 × 10G SFP+, ZJRing/ERPS ring, AC/DC 100–240V.

Who it is for

  • Utilities and substations — IEC61850-3 compliant, Level 3 EMS immunity and AC/DC 100–240V input; a Layer 3 station core whose 4 × 10G SFP+ links tie the station LAN to the control centre or a second core.
  • CCTV and ITS control rooms — A 10G ring or star between cores, NVR storage and video walls: 4 × 10G SFP+ for the heavy links and 24 Gigabit copper ports for recorders, decoders and client PCs in the same rack.
  • Factories, mining and oil & gas plants — 24 Gigabit copper ports for control-room PCs, servers and PLC gateways, 64 VLANs to keep OT, IT and video apart, ACL and 802.1X for access control, and a -40 to 75°C wide-temperature version.
  • System integrators and OEM projects — One 1U box replaces a separate router and core switch on mid-size projects: OSPF, RIPv1/v2, static routes and VRRPv2 for a redundant gateway, managed by Web, Telnet, console CLI and SNMPv1/v2/v3.

Where and how to install

  • 19-inch rack, 1U, with depth to spare — The body is 440 × 44 × 310 mm and mounts in a standard 19-inch rack, not on DIN rail. Allow extra depth behind it for the power and alarm terminals and in front for fibre patch cords with a gentle bend radius.
  • Power: AC/DC 100–240V, order dual input for redundancy — Input is via a 4-pin power terminal; single or dual power supply is an ordering option, so specify dual if you want to feed it from two sources (for example UPS mains and the station DC system). Maximum consumption is 35 W.
  • Wire the alarm relay and ground the chassis — Use the 2-pin alarm terminal (rated 220V, max 2A) to signal a power or link fault to the SCADA or a buzzer. Bond the chassis to the rack earth bar with a short conductor; the Level 3 surge and EFT immunity depends on a good earth.
  • 10G fibre: SFP+ modules matched at both ends — The 4 SFP+ slots take 10GBase-X modules; both ends of a link need the same speed, fibre type (single-mode or multimode) and wavelength pair. 10G optics are less tolerant of dirty connectors than 1G, so clean every connector before plugging in and keep dust caps on unused slots.
  • Temperature and condensation — The standard model runs at -10 to 60°C and the wide-temperature model at -40 to 75°C; choose the wide model for unconditioned shelters. Humidity must stay within 5–95% non-condensing, and the IP40 case is for indoor cabinets only, so use a heater or ventilation where dew forms.
  • Plan management before go-live — Keep the RS-232 console (RJ45, 9600 bps, 8-N-1) cable in the cabinet for recovery, set a management VLAN, change the login password, and export the configuration file after commissioning so a replacement unit can be restored quickly.

Ports & ring planning

All fibre on this model is 10G: 4 SFP+ slots and no separate 1G SFP slots. The 24 copper ports at full Gigabit (24 Gbps) are less than the 4 SFP+ slots together (40 Gbps), so the uplinks are not the bottleneck; two 10G links can also form a ring with two left for storage or a second core.

ZJIES6028M-HI-24GT4S+
Copper ports24 × 10/100/1000Base-T (RJ45)
1G fibre slotsNone
10G fibre slots4 × 10GBase-X SFP+
Total line rate (one direction)24 + 40 = 64 Gbps
Access vs 10G uplink24 Gbps copper ≤ 40 Gbps SFP+
Ring protocolsZJRing (< 20 ms), ERPS G.8032, STP/RSTP/MSTP
Layer 3Static, RIPv1/v2, OSPF, VRRPv2, PIM-DM/SM, IPv6 static
VLAN / link aggregation64 VLANs (VID 1–4094) · 2 LACP groups × 4 ports
MulticastIGMP Snooping v1/v2, 256 groups
Power input / consumptionAC/DC 100–240V, single or dual · max 35 W
Operating temperature-10~60°C standard · -40~75°C wide
Housing / mountingIP40 metal · 19-inch 1U rack
  • Pick this model for a 10G backbone where every fibre link is 10G and local devices connect on copper.
  • If field cabinets or older switches arrive on Gigabit fibre, choose the ZJIES6028M-HI-24GT4GB4S+, which adds 4 × 1G SFP to the same 24 copper + 4 SFP+.
  • Use ZJRing (< 20 ms) when every switch in the ring is Zhongxin; use ERPS G.8032 or RSTP/MSTP when the ring mixes brands.

Values from the manufacturer's ZJIES6028M-HI series datasheet. Line-rate totals are simple sums of port speeds; fibre reach is not a switch spec and depends on the SFP/SFP+ modules you fit.

24-Port L3 Switch with 10G Uplink FAQ — ZJIES6028M-HI-24GT4S+

What are the 4 x 10G SFP+ uplinks used for?
The 4 x 10GBase-X SFP+ slots carry aggregated traffic from the 24 x 10/100/1000Base-T copper access ports up to a 10-Gigabit backbone or core. This is the first model in the Zhongxin Shutong lineup with a 10-Gigabit uplink, sized for camera-heavy or data-heavy sites. Transceiver modules are ordered separately.
Does the ZJIES6028M-HI-24GT4S+ replace a separate router?
For routed uplinks, yes: it supports static routes, RIPv1/v2, OSPF, IPv6 static routing, policy routing for IPv4/IPv6, VRRPv2 gateway redundancy, and PIM-DM/PIM-SM multicast routing at Layer 3. DHCP server, relay and snooping are built in, so inter-VLAN routing and address assignment run on the switch itself.
How quickly does the ring heal if a backbone link fails?
Ring resilience combines proprietary ZJRing self-healing with recovery under 20 ms, ERPS (G.8032), STP/RSTP/MSTP spanning tree, and VRRP-based Ethernet ring protection recovering in under 200 ms. That keeps surveillance streams and industrial control traffic running through a single link failure on the loop.
What management and security options are included?
Management runs over serial CLI (RS-232 console, RJ45, 9600, 8, N, 1), Web, Telnet and SNMP v1/v2/v3, with LLDP, Syslog, RMON, SNTP and NTP. Security covers 802.1X port access control, ACLs, port and MAC filtering, IP Source Guard, ARP proxy and DHCP snooping across 64 VLAN groups (VID 1-4094).
How is it installed and what capacity does it offer?
It mounts in a standard 19-inch rack at 1U height and runs on AC 220V, with a -40 to 75 C operating range for harsh rooms. Switching uses store-and-forward with a 16K MAC table and 12 Mbit buffer; static LACP provides 2 groups of up to 4 ports, and IGMP Snooping v1/v2 handles 256 multicast groups.
Can I put 1G SFP modules in the SFP+ slots of the ZJIES6028M-HI-24GT4S+ to connect older Gigabit switches?
The datasheet lists the slots only as 10GBase-X SFP+ and does not say whether they also run 1G modules, so confirm with us before ordering if your design depends on it. Both ends of a fibre link must run at the same speed. If you have several Gigabit fibre links to terminate, the ZJIES6028M-HI-24GT4GB4S+ has 4 dedicated 1G SFP slots in addition to the 4 SFP+.
Which 10G SFP+ modules should I order for the ZJIES6028M-HI-24GT4S+, and how far will they reach?
Reach depends on the module, not the switch: multimode modules suit short runs inside a building or control room, single-mode modules suit links between buildings or stations. The datasheet has no module compatibility list, so tell us the fibre type, distance and far-end device and we will supply matched SFP+ modules. For the -40 to 75°C wide-temperature model, use industrial-temperature modules as well.
Can the ZJIES6028M-HI-24GT4S+ form a 10G ring with other brands' core switches?
Yes, through a standard protocol: it lists ERPS (ITU-T G.8032), RSTP, MSTP and STP, which other managed brands also support. ZJRing, with self-healing under 20 ms, is Zhongxin's private ring and works only between Zhongxin switches. In a mixed ring, plan the ring ID, control VLAN and RPL owner the same way on every node and keep all ring links at 10G.
Can the ZJIES6028M-HI-24GT4S+ be powered from a 110V or 220V DC station battery?
The datasheet gives the input range as AC/DC 100–240V, so a 110V or 220V DC station supply falls inside it, as does normal AC mains. Order the dual-power version if you want one input from the DC system and one from AC, and wire the 2-pin alarm terminal so the loss of either input is reported. There is no 24V or 48V DC version of this model in the datasheet.
How does the ZJIES6028M-HI-24GT4S+ handle multicast video and IEC 61850 GOOSE?
IGMP Snooping v1/v2 with up to 256 multicast groups stops multicast streams flooding every port, and PIM-DM/PIM-SM can route multicast between subnets. GOOSE frames are Layer 2 multicast, so keep them in their own VLAN and use 802.1p priority (4 priority queues with strict or weighted scheduling) to put them ahead of video. Broadcast, multicast and unknown-unicast storm suppression is also available to protect the network.
How many camera streams can pass through one 10G link on the ZJIES6028M-HI-24GT4S+?
Assuming 4 Mbps per 4 MP camera stream and planning the link at about 70% load, one 10G SFP+ link carries roughly 1,750 streams (7,000 ÷ 4). Each copper port at 1 Gbps carries roughly 175 on the same assumption, which is the practical limit for an edge PoE switch or NVR connected on copper. The switch has no PoE, so cameras are powered by edge PoE switches.
What power connector does the ZJIES6028M-HI-24GT4S+ have, and do I need to confirm it before ordering?
Yes, please confirm the power connector with us before ordering. For Zhongxin Shutong products the power input type and connector can differ between versions and batches, so tell us your supply (AC or DC and the voltage), how you will wire it in the cabinet and your country's plug standard, and we confirm the exact connector and supply version of the ZJIES6028M-HI-24GT4S+ for your order.
Can I order one unit first, and how does it reach my country?
Yes — a single sample can be ordered and sent by air. For larger orders we deliver EXW or FOB to your freight forwarder's warehouse in China, or arrange air or sea freight to your country on request. Every shipment comes with a commercial invoice and packing list for customs; import duties and VAT in your country are not included unless agreed in writing.
How do I pay?
By bank transfer (T/T) in US dollars against our proforma invoice, which lists the model, quantity, unit price, delivery terms and lead time. You can check our company details on the verification page before you pay.
Our own line — Zhongxin Shutong industrial switches1,500 m² clean rooms100% port-by-port tested-40…+75 °C rated, cycled to +85 °CEN 61000-4 Level 3 EMC immunitySerial-number traceability on every unitISO 9001 · 14001 · 27001 · CMMI L3See the factory →See all certifications →

Every order, any brand: there is no return policy — defective units are covered by free spare units agreed per order and written into the quotation. Warranty up to 5 years on the Zhongxin Shutong industrial line, manufacturer warranty on other brands. Terms, warranty & RMA

Request a quote for this product

An engineer replies within 24 hours on working days with model check, price and lead time. No obligation, no newsletters.

Product: ZJIES6028M-HI-24GT4S+

For a fast, exact quote tell us: model or requirement · quantity · destination country / port · EXW or FOB · deadline.

Or ask on WhatsApp

Zhengzhou Huamai Information Technology Co., Ltd. · Tel / WhatsApp +86 186 1168 3168 · info@atlascommtech.com